1,487 research outputs found

    Antenna pattern of DUAL detectors of gravitational waves and its exploitation in a network of advanced interferometers

    Get PDF
    We investigate the directional sensitivity to plane gravitational waves (GWs) of DUAL detectors of cylindrical shape. Calculations make use of the finite element method to simulate the responses to the GW Riemann tensor of a single-mass DUAL (SMD) and of a tapered cylinder (TC) in their wide sensitivity bandwidth. We show that one SMD or a pair of TCs is able to cover both GW polarization amplitudes from almost all incoming directions. We discuss the achievable enhancement in tackling the inverse problem for high frequency [~(2–5) kHz] GWs by adding a TC detector to the future advanced LIGO–VIRGO network

    False discovery rate: setting the probability of false claim of detection

    Full text link
    When testing multiple hypothesis in a survey --e.g. many different source locations, template waveforms, and so on-- the final result consists in a set of confidence intervals, each one at a desired confidence level. But the probability that at least one of these intervals does not cover the true value increases with the number of trials. With a sufficiently large array of confidence intervals, one can be sure that at least one is missing the true value. In particular, the probability of false claim of detection becomes not negligible. In order to compensate for this, one should increase the confidence level, at the price of a reduced detection power. False discovery rate control is a relatively new statistical procedure that bounds the number of mistakes made when performing multiple hypothesis tests. We shall review this method, discussing exercise applications to the field of gravitational wave surveys.Comment: 7 pages, 3 table, 3 figures. Prepared for the Proceedings of GWDAW 9 (http://lappc-in39.in2p3.fr/GWDAW9) A new section was added with a numerical example, along with two tables and a figure related to the new section. Many smaller revisions to improve readibilit

    Oxidation of sulphur dioxide in water droplets in the presence of ammonia

    Get PDF
    SO2 oxidation by oxygen in monodisperse water droplets was studied in a cylindrical chamber, without and in the presence of ammonia. The range of SO2 concentration was from about 1022 to 5 ppmv, while the NH3 input concentration was kept constant at about 4.731022 ppmv. The contact time between gases and droplets was 210 s. The experimental results were compared with the theoretical values predicted by the kinetics of Larson et al. (Atmos. Environ., 12 (1978) 1597) and McKay (Atmos. Environ., 5 (1971) 7). Much higher sulphate concentrations were obtained in experiments run in the presence of NH3, as opposed to those without NH3. The experimental results agree with the values predicted by McKay’s kinetics and are higher than Larson’s

    SO2 oxidation in supercooled droplets in the presence of O2

    Get PDF
    Sulphur dioxide oxidation in supercooled monodisperse droplets at T4213 7C was studied in the presence of oxygen. The SO2 concentration was found to range from 0.08 to 7.1 ppmv and the contact time between gases and droplets was 210 s. The experimental results showed that sulphate concentration due to SO2 oxidation is independent of temperature, i.e. the increase of SO2 solubility in the liquid phase balances the rate constant decrease of the oxidation reaction. Following McKay’s kinetics (Atmos. Environ., 5 (1971) 7), we calculated the rate constant at T4213 7C and the activation energy. A comparison was made between experimental S(VI) oxidation concentrations due to oxygen and theoretical oxidation values due to O3, H2O2 and oxygen in the presence of catalyzers (Fe31, Mn21)

    Inhomogeneous mechanical losses in micro-oscillators with high reflectivity coating

    Full text link
    We characterize the mechanical quality factor of micro-oscillators covered by a highly reflective coating. We test an approach to the reduction of mechanical losses, that consists in limiting the size of the coated area to reduce the strain and the consequent energy loss in this highly dissipative component. Moreover, a mechanical isolation stage is incorporated in the device. The results are discussed on the basis of an analysis of homogeneous and non-homogeneous losses in the device and validated by a set of Finite-Element models. The contributions of thermoelastic dissipation and coating losses are separated and the measured quality factors are found in agreement with the calculated values, while the absence of unmodeled losses confirms that the isolation element integrated in the device efficiently uncouples the dynamics of the mirror from the support system. Also the resonant frequencies evaluated by Finite-Element models are in good agreement with the experimental data, and allow the estimation of the Young modulus of the coating. The models that we have developed and validated are important for the design of oscillating micro-mirrors with high quality factor and, consequently, low thermal noise. Such devices are useful in general for high sensitivity sensors, and in particular for experiments of quantum opto-mechanics

    Selective readout and back-action reduction for wideband acoustic gravitational wave detectors

    Full text link
    We present the concept of selective readout for broadband resonant mass gravitational wave detectors. This detection scheme is capable of specifically selecting the signal from the contributions of the vibrational modes sensitive to the gravitational waves, and efficiently rejecting the contribution from non gravitationally sensitive modes. Moreover this readout, applied to a dual detector, is capable to give an effective reduction of the back-action noise within the frequency band of interest. The overall effect is a significant enhancement in the predicted sensitivity, evaluated at the standard quantum limit for a dual torus detector. A molybdenum detector, 1 m in diameter and equipped with a wide area selective readout, would reach spectral strain sensitivities 2x10^{-23}/sqrt{Hz} between 2-6 kHz.Comment: 9 pages, 4 figure

    Prospects for intermediate mass black hole binary searches with advanced gravitational-wave detectors

    Get PDF
    We estimated the sensitivity of the upcoming advanced, ground-based gravitational-wave observatories (the upgraded LIGO and Virgo and the KAGRA interferometers) to coalescing intermediate mass black hole binaries (IMBHB). We added waveforms modeling the gravitational radiation emitted by IMBHBs to detectors' simulated data and searched for the injected signals with the coherent WaveBurst algorithm. The tested binary's parameter space covers non-spinning IMBHBs with source-frame total masses between 50 and 1050 M⊙\text{M}_{\odot} and mass ratios between 1/61/6 and 1 \,. We found that advanced detectors could be sensitive to these systems up to a range of a few Gpc. A theoretical model was adopted to estimate the expected observation rates, yielding up to a few tens of events per year. Thus, our results indicate that advanced detectors will have a reasonable chance to collect the first direct evidence for intermediate mass black holes and open a new, intriguing channel for probing the Universe over cosmological scales.Comment: 9 pages, 4 figures, corrected the name of one author (previously misspelled

    Detection of weak stochastic force in a parametrically stabilized micro opto-mechanical system

    Full text link
    Measuring a weak force is an important task for micro-mechanical systems, both when using devices as sensitive detectors and, particularly, in experiments of quantum mechanics. The optimal strategy for resolving a weak stochastic signal force on a huge background (typically given by thermal noise) is a crucial and debated topic, and the stability of the mechanical resonance is a further, related critical issue. We introduce and analyze the parametric control of the optical spring, that allows to stabilize the resonance and provides a phase reference for the oscillator motion, yet conserving a free evolution in one quadrature of the phase space. We also study quantitatively the characteristics of our micro opto-mechanical system as detector of stochastic force for short measurement times (for quick, high resolution monitoring) as well as for the longer term observations that optimize the sensitivity. We compare a simple, naive strategy based on the evaluation of the variance of the displacement (that is a widely used technique) with an optimal Wiener-Kolmogorov data analysis. We show that, thanks to the parametric stabilization of the effective susceptibility, we can more efficiently implement Wiener filtering, and we investigate how this strategy improves the performance of our system. We finally demonstrate the possibility to resolve stochastic force variations well below 1% of the thermal noise
    • …
    corecore